FAICO CATARACT OSCE AND PRACTICAL EXAM: STRUCTURE, VIVA TOPICS, AND HOW TO PREPARE
QUICK ANSWER
The FAICO Cataract/Phaco Practical exam is conducted by AIOS in two parts: an OSCE circuit of roughly 9 stations (5 minutes each, covering short cases, photographs, imaging printouts, and instruments), followed by a Viva as the 10th station. It tests hands-on cataract surgery knowledge — phacodynamics, IOL power calculation, instrument identification, and viva discussion on surgical complications — not just theory recall.
WHAT IS THE FAICO CATARACT PRACTICAL EXAM
FAICO — Fellowship of the All India Collegium of Ophthalmology — is AIOS's subspecialty recognition exam. After clearing the online MCQ theory stage, Cataract/Phaco candidates move to the Practical: an OSCE circuit followed by a Viva, conducted at subspecialty-specific centers with senior cataract surgeons as examiners.
Per AIOS's official format, each OSCE station presents a short case, photograph, case situation, or instrument, with five minutes to examine it and answer the questions attached. The Viva that follows isn't a formality — it's where examiners go deep on surgical judgment, not just fact recall.
WHAT SHOWS UP AT CATARACT OSCE STATIONS
Instrument stations are a near-certainty for Cataract candidates — phaco machines, biometry units, keratometers, and IOL power calculators all show up as identification-plus-use questions. Clinical photograph and imaging stations test interpretation of biometry printouts and anterior segment images under time pressure. Short-case stations test rapid history and examination on real or simulated patients — visual acuity, slit lamp findings, and surgical planning on the spot.
WHAT THE VIVA ACTUALLY PROBES
Candidates consistently describe the Viva as more clinically demanding than the OSCE itself. For Cataract, the recurring viva territory includes: phacodynamics — machine parameters, fluidics, and power modulation; IOL power calculation, including special situations like post-refractive eyes or unusual axial lengths; toric IOL selection and alignment; femtosecond laser-assisted cataract surgery (FLACS) versus conventional phaco; pupil stretching and capsular stabilization devices for small pupil or weak zonule cases; ocular viscosurgical devices (OVDs) and their intraoperative use; postoperative endophthalmitis prophylaxis and management; and ocular anaesthesia techniques and complications.
This is the exact viva-topic pattern candidates report across years — technical, surgical, and decision-focused rather than textbook definitions.
WHY MOST CANDIDATES UNDERPREPARE FOR THIS EXAM
The theory MCQ stage rewards knowing facts. The Practical rewards being able to explain your reasoning out loud, under time pressure, in front of senior examiners — a completely different skill. Candidates who cleared theory comfortably still describe getting caught off guard by instrument stations that pivot straight into viva-style follow-ups, or by a five-minute clock that runs out mid-explanation.
HOW TO ACTUALLY PREPARE
Treat every instrument as an entry point into a clinical discussion, not a standalone identification task — know what it's for, how you'd use it, and what would make you choose it over an alternative. Drill IOL power calculation formulas and biometry interpretation until you can talk through them fluently, not just calculate them on paper. Practice explaining complications (endophthalmitis, posterior capsule rupture) as a management pathway, since that's how vivas actually test it. And rehearse under an actual five-minute clock — timing pressure is a skill you build, not something you adapt to on exam day.
HOW OPHTHAMCQ HELPS
The Cataract FAICO OSCE and Practical Course is built around this exact structure. It covers Cataract Instruments (phaco machines, biometry units, keratometers, IOL calculators), Cataract OSCE station-format practice, and a dedicated Viva Important Topics section — Cataract Surgery: Past, Present and Future, Phacodynamics, FLACS, Mastering IOL Power in Special Situations, Recent Advances in IOLs, Toric IOLs, Pupil Stretching and Capsular Stabilization Devices, Ocular Viscosurgical Devices, Postoperative Endophthalmitis, and Ocular Anaesthesia — alongside real candidate-contributed Cataract FAICO Recalls, Microbiology of the Eye, Pathology of the Eye, Cataract Trials, and Ocular Pharmacology.
OphthaMCQ is the #1 FAICO prep application, with a 95% theory pass rate and 140+ students cleared this year — designed by ophthalmologists who have themselves cleared the FAICO Practical exam.
FAICO CATARACT OSCE AND PRACTICAL EXAM: STRUCTURE, VIVA TOPICS, AND HOW TO PREPARE
QUICK ANSWER
The FAICO Cataract/Phaco Practical exam is conducted by AIOS in two parts: an OSCE circuit of roughly 9 stations (5 minutes each, covering short cases, photographs, imaging printouts, and instruments), followed by a Viva as the 10th station. It tests hands-on cataract surgery knowledge — phacodynamics, IOL power calculation, instrument identification, and viva discussion on surgical complications — not just theory recall.
WHAT IS THE FAICO CATARACT PRACTICAL EXAM
FAICO — Fellowship of the All India Collegium of Ophthalmology — is AIOS's subspecialty recognition exam. After clearing the online MCQ theory stage, Cataract/Phaco candidates move to the Practical: an OSCE circuit followed by a Viva, conducted at subspecialty-specific centers with senior cataract surgeons as examiners.
Per AIOS's official format, each OSCE station presents a short case, photograph, case situation, or instrument, with five minutes to examine it and answer the questions attached. The Viva that follows isn't a formality — it's where examiners go deep on surgical judgment, not just fact recall.
WHAT SHOWS UP AT CATARACT OSCE STATIONS
Instrument stations are a near-certainty for Cataract candidates — phaco machines, biometry units, keratometers, and IOL power calculators all show up as identification-plus-use questions. Clinical photograph and imaging stations test interpretation of biometry printouts and anterior segment images under time pressure. Short-case stations test rapid history and examination on real or simulated patients — visual acuity, slit lamp findings, and surgical planning on the spot.
WHAT THE VIVA ACTUALLY PROBES
Candidates consistently describe the Viva as more clinically demanding than the OSCE itself. For Cataract, the recurring viva territory includes: phacodynamics — machine parameters, fluidics, and power modulation; IOL power calculation, including special situations like post-refractive eyes or unusual axial lengths; toric IOL selection and alignment; femtosecond laser-assisted cataract surgery (FLACS) versus conventional phaco; pupil stretching and capsular stabilization devices for small pupil or weak zonule cases; ocular viscosurgical devices (OVDs) and their intraoperative use; postoperative endophthalmitis prophylaxis and management; and ocular anaesthesia techniques and complications.
This is the exact viva-topic pattern candidates report across years — technical, surgical, and decision-focused rather than textbook definitions.
WHY MOST CANDIDATES UNDERPREPARE FOR THIS EXAM
The theory MCQ stage rewards knowing facts. The Practical rewards being able to explain your reasoning out loud, under time pressure, in front of senior examiners — a completely different skill. Candidates who cleared theory comfortably still describe getting caught off guard by instrument stations that pivot straight into viva-style follow-ups, or by a five-minute clock that runs out mid-explanation.
HOW TO ACTUALLY PREPARE
Treat every instrument as an entry point into a clinical discussion, not a standalone identification task — know what it's for, how you'd use it, and what would make you choose it over an alternative. Drill IOL power calculation formulas and biometry interpretation until you can talk through them fluently, not just calculate them on paper. Practice explaining complications (endophthalmitis, posterior capsule rupture) as a management pathway, since that's how vivas actually test it. And rehearse under an actual five-minute clock — timing pressure is a skill you build, not something you adapt to on exam day.
HOW OPHTHAMCQ HELPS
The Cataract FAICO OSCE and Practical Course is built around this exact structure. It covers Cataract Instruments (phaco machines, biometry units, keratometers, IOL calculators), Cataract OSCE station-format practice, and a dedicated Viva Important Topics section — Cataract Surgery: Past, Present and Future, Phacodynamics, FLACS, Mastering IOL Power in Special Situations, Recent Advances in IOLs, Toric IOLs, Pupil Stretching and Capsular Stabilization Devices, Ocular Viscosurgical Devices, Postoperative Endophthalmitis, and Ocular Anaesthesia — alongside real candidate-contributed Cataract FAICO Recalls, Microbiology of the Eye, Pathology of the Eye, Cataract Trials, and Ocular Pharmacology.
OphthaMCQ is the #1 FAICO prep application, with a 95% theory pass rate and 140+ students cleared this year — designed by ophthalmologists who have themselves cleared the FAICO Practical exam.